Home
Products
Support
About us
Contacts
+7 863 218 2475 info@vibrobit.ru
Contents

ИП34Ex, Converter

Description

ИП34Ex, Converter

Converter ИП34Ех for measurement of displacement and relative vibration displacement in combination with Eddy-current sensor ДВТ10Ех; ДВТ20Ех at temperatures from -40 to +70 °C. The 1...5; 4…20 mA DC output signal is proportional to the displacement of the target surface relative to the sensor.

Used together with the controllers of the "Vibrobit 300" and "Vibrobit 500" systems.

Key features:

  • explosionproof version 1ExibIIBT3 GbX
  • Type of explosion protection — intrinsically safe electrical circuit "i"
  • Requirement to be connected into intrinsically safe electrical circuits
  • Installation in special metal converter boxes

Specifications

Measured parameter displacement
relative vibration displacement
Compatibility with sensor Eddy-current ДВТ10Ех;
Eddy-current ДВТ20Ех;
Measurement range 0 — 2 mm (ДВТ10Ех)
0 — 4 mm (ДВТ20Ех)
Frequency range 0.05 - 1500 Hz  (relative vibration displacement)
Explosion protection Yes
explosion protection type intrinsically safe electrical circuit "i"
Explosion protection marking 1Ex ib IIB T3 Gb X
Special explosion protection requirements Connection via intrinsically safe barriers;
Installation in an explosion-proof converter box
Registry number 50585-12
Limits of permissible basic measurement error, % ±2,5 (relative accuracy)
Calibration interval, years 2
Output type 4 — 20 mA DC
Load resistance, Ohm  (max) 500
Connection diagram (number of lines) 4-wire
Power supply voltage range, V +(18-25,2)*
Current consumption, (max) mА 45
Operating temperature range, °С from −40 to +70
Housing index of protection according to GOST 14254 IP32
Sensor connection type РСГ7ТВ
Cable connection type screw terminal block
Overall dimensions, mm 127*62*34
Service life, years (min.) 10
Warranty period, months 24
MTBF, hours 150 000
*) When powered through an intrinsically safe barrier of the БИБ-02DP-22 type, the supply voltage is: + (21.5 – 25.2) VDC.


Applications

Measurement of the  displacement; rotor vibration displacement; rotor bow (eccentricity); rotor axial shift with Eddy-current sensor ДВТ10Ex; ДВТ20Ex in steam, gas and hydraulic turbine units, turbocompressors, centrifugal pumps and other machines during their operation.
The sensor can be used both independently and as part of the measurement channels of the plant's SCADA systems.

Dimensions and connection diagram