СП10, Stand
Description
Stand СП10 intended for calibration and testing of the eddy current sensors ДВТ10, ДВТ20, ДВТ21, ДВТ30 in conjunction with the transducers.
The displacement of the reference surface of the sample is produced by rotating the micrometer depth gauge, and the displacement parameter is read off its scale.
When calibrating the sensors, a reference sample made of the material of the object being tested must be used. The СП10 kit includes a reference sample made of structural steel.
Specifications
| Параметр | Значение |
|---|---|
| Displacement range, mm | 0 – 25 |
| Limits of permissible basic measurement error, mm | ±0.01 |
| Parallelism tolerance between the reference sample and the sensor surface, mm | 0.2 |
| Overall dimensions, mm | 150×100×65 |
| Weight (max), kg | 0.5 |
Applications
Dimensions and connection diagram